An overview of the

Mitsubishi AnS Series PLC Family:

	 Processors [1 page down]		 CPUs [2 pages down]

			 I/O Modules [3 pages down]

 Communications Modules [4 pages down]		 Remote I/O [5 pages down]

Base racks: Expansion racks:
A1S33B - Power Supply (P/S), CPU, 3 I/O slots, 225mm wide A1S52B-S1 - 2 I/O slots, 155mm wide
A1S55B-S1 - 5 I/O slots, 260mm wide
A1S35B - P/S, CPU, 5 I/O slots, 325mm wide A1S58B-S1 - 8 I/O slots, 365mm wide
A1S65B-S1 - P/S, 5 I/O slots, 315mm wide
A1S38B - P/S, CPU, 8 I/O slots, 430mm wide
A1S68B-S1 - P/S, 8 I/O slots, 420mm wide

Power Supplies:
A1S61P - AC 110V/220V Input, 5 Volts/5 Amps Output
A1S62P - AC 110V/220V Input, 5 Volts/3 Amps plus 24 Volts/0.6 Amps Output
A1S63P - DC 24V Input, 5 Volts/5 Amps Output

Processors:

Standard CPU - 1.25 ms per 1K step processing speed Advanced CPU - For high speed processing, floating point math, more data storage: For OEM (low cost) applications:
A1SCPU - 8K program steps, 256 I/O point maximum addressing A2ASCPU- 14K steps, 0.2 ms per 1K steps speed, 512 I/O A1SJCPU - 5 Slot rack, 5V/3A power supply, A1S CPU integrated into a single unit - connects to standard expansion racks.
A1SCPUC24-R2 - 8K program steps, 256 I/O point maximum addressing (With built in RS-232 communications card)
A1SCPU-S1 - 8K program steps, 512 I/O points
A2SCPU - 14K program steps, 512 I/O points A2ASCPU-S30 - 30K steps, 0.2 ms per 1K steps speed, 1024 I/O A1SJCPU-S8 - 8 Slot rack, 5V/3A power supply, A1S CPU integrated into a single unit - connects to standard expansion racks.
A2SCPU-S1 - 14K program steps, 1024 I/O points

Standard CPU's have:
  • 1.25 ms per 1K instructions average processing speed
  • Direct or Refresh type I/O processing
  • Switch back and forth between Instruction List or Ladder type programming
  • 26 simple logic instructions, 235 data manipulation instructions
  • Watch Dog Timer 10 ms to 2000 ms programmable

  • 2048 internal relays, normal or retentive
  • 1024 link relays for network communications or general use
  • 256 timers, 100 ms or 10 ms timebase, normal or retentive
    • 256 counters
    • 256 program jump pointers
    • 32 program interrupt pointers

  • 1024 data registers, 16 bit signed or unsigned data, normal or retentive
    • Any two adjacent registers are used to make 32 bit data operations.
    • All registers may be used for binary or BCD operations.
  • 1024 link registers, for network comms or general use as data registers

  • Up to 4096 file registers
    • use like data registers, but are always retentive and cannot be accidentally cleared with "latch memory clear" function
  • 256 Annunciator points:
    • Use for alarm tracking - automatic FIFO system for alarm activation and clearing.
  • 2 general purpose 16 bit accumulator registers for mathematics use.
  • 2 index registers allowing VERY powerful table access and data indexing.

  • 256 system diagnostic memory points, 256 system diagnostic registers
  • CPU's support program change during run and "pause" feature which allows CPU to stop processing but keeps all outputs active.
All AnS Series CPU's are software compatibile with "full size" A-Series.

Advanced CPU's (A2AS, A2AS-S30) have:
  • 0.2 ms per 1K instructions average processing speed
  • Refresh type I/O processing
  • Switch back and forth between Instruction List or Ladder type programming
    • 26 simple logic instructions
    • 239 data manipulation instructions
    • 200 dedicated advanced function instructions
  • Watch Dog Timer 200 ms fixed
  • 8192 internal relays, normal or retentive
  • 4096 link relays for network communications or general use
  • 2048 timers, 100 ms or 10 ms timebase, normal or retentive
  • 2048 counters
  • 256 program jump pointers
  • 32 program interrupt pointers
  • 6144 data registers, 16 bit signed or unsigned data, normal or retentive
    • Any two adjacent registers are used to make 32 bit data operations.
    • All registers may be used for binary or BCD operations.
  • 4096 link registers, for network comms or general use as data registers
  • Up to 8192 file registers
    • use like data registers, but are always retentive and cannot be accidentally cleared with "latch memory clear" function
  • Extension file registers programmable in banks of 4096
  • 2048 Annunciator points
    • Use for alarm tracking - automatic FIFO system for alarm activation and clearing.
  • 2 general purpose 16 bit accumulator registers for mathematics use.
  • 14 index registers allowing VERY powerful table access and data indexing.
  • 256 system diagnostic memory points, 256 system diagnostic registers
  • CPU's support program change during run and "pause" feature which allows CPU to stop processing but keeps all outputs active.
All AnS Series CPU's are software compatibile with "full size" A-Series.

Input modules available are: Output modules available are:
A1SX10 16 in, 120V AC, removable barrier strip A1SY10 16 out, 2 amp relay, 8 per common, removable barrier strip
A1SX20 16 in, 240V AC, removable barrier strip A1SY18A8 out, 2 amp relay, 1 per common, removable barrier strip
A1SX30 16 in, 12/24 V AC/DC, removable barrier strip A1SY22 16 out, 0.6 amp triac, 8 per common, 120/240V AC, removable barrier strip
A1SX40 16 in, 12/24 V DC Sink (NPN type), 10 ms ON/OFF, removable barrier strip A1SY28A 8 out, 0.6 amp triac, 1 per common, 120/240V AC, removable barrier strip
A1SX40-S1 16 in, 24 V DC Sink (NPN type), 0.1 ms ON, 0.2 ms OFF, removable barrier strip A1SY40 16 out, 12/24 V DC, 0.1 amp NPN transistor, 8/common, removable barrier strip
A1SX41 32 in, 12/24 V DC Sink (NPN type), 10 ms ON/OFF, FCN connector A1SY41 32 out, 12/24 V DC, 0.1 amp NPN transistor, 32/common, FCN connector
A1SX42 64 in, 12/24 V DC Sink (NPN type), 10 ms ON/OFF, FCN connectors A1SY42 64 out, 12/24 V DC, 0.1 amp NPN transistor, 32/common, FCN connectors
A1SX71 32 in, 5/12 V DC (TTL Compatible), 1.5 ms ON, 3 ms OFF, FCN connector A1SY50 16 out, 12/24 V DC, 0.5 amp NPN transistor, 8/common, removable barrier strip
A1SX80 16 in, 12/24 V DC Source (PNP type), 10 ms ON/OFF, removable barrier strip A1SY6016 out, 24 V DC, 2 amp NPN transistor, 8/common, removable barrier strip
A1SY60E 16 out, 5/12/24 V DC, 2 amp NPN transistor, 8/common, removable barrier strip
A1SX80-S1 16 in, 24 V DC Source (PNP type), 0.4 ms ON, 0.5 ms OFF, removable barrier strip A1SY68A 8 out, 5/12/24/48 V DC, 2 amp NPN transistor, 1/common, removable barrier strip
A1SY71 32 out, 5/12 V DC (NPN/TTL Compatible), 1 ms ON/OFF, FCN connector
A1SX81 32 in, 12/24 V DC Source (PNP type), 10 ms ON/OFF, DB-37 connector A1SY80 16 out, 12/24 V DC, 0.8 amp PNP transistor, 2 ms ON/OFF, removable barrier strip
A1SY81 32 out, 12/24 V DC, 0.1 amp PNP transistor, 2 ms ON/OFF, DB-37 connector
All input and output modules are opto-coupler isolated from the internal circuits.

Special function modules:

Communications Modules:
  • A1SJ71C24-R2 - RS-232C intelligent communications adapter
    Full or half duplex communications
    4 dedicated remote enquiry protocols for data access/remote programming
    "no protocol" mode - communications driven by ladder program
    "bi-directional" mode - point to point PLC communications
    protocol switchable by ladder program
    switch settable 300 to 19,200 baud

  • A1SJ71C24-PRF - RS-232C intelligent communications adapter/printer controller
    All functions of A1SJ71C24-R2, plus:
    up to 31 variable messages stored
    up to 400 fixed messages stored
    each message up to 80 characters long

  • A1SJ71C24-R4 - RS-422/485 intelligent communications adapter
    All functions of A1SJ71C24-R2, plus:
    Long distance communications via balanced twisted pair
    Multidrop communications addressable (up to 32 stations)
    PLC to PLC networking (up to 8 stations)

  • A1SJ71E71-B2, B5 - Ethernet communications modules
    All functions of A1SJ71C24-R2, over 10BASE2 or 10BASE5 ethernet
    Communications via TCP/IP, UDP/IP protocols

  • A1SD51S - BASIC language intelligent communications module
    Two RS-232 and one RS-422 port
    one or two BASIC tasks run at one time

Analog I/O Modules
  • A1S64AD - 4 channel analog input
    0 - 10V, 0 - 5V, 1 - 5V, -10 - +10V, 4-20 mA, 0-20mA, -20 - 20mA
    Digital calibration allows other range settings
    maximum resolution: -12,288 to +12,288
    20 ms to digitize 4 channels
    programmable sampling/averaging
    removable barrier strip

  • A1S68AD - 8 channel analog input
    0 - 10V, 0 - 5V, 1 - 5V, -10 - +10V, 4-20 mA, 0-20mA
    (factory calibrations selectable from above ranges)
    maximum resolution: 0 to 4000 (-2000 - 2000)
    0.5 ms per channel digitizing speed
    programmable sampling/averaging
    removable barrier strip

  • A1S62DA - 2 channel analog output
    0 - 10V, 0 - 5V, 1 - 5V, -10 - +10V, 4-20 mA, 0-20mA, -20 - 20mA
    Digital calibration allows other range settings
    Maximum resolution: -12,000 to +12,000
    25 ms to convert analog output
    removable barrier strip

  • A1S68DAV - 8 channel analog output, -10V to 0 to 10V
    (factory calibrated)
    resolution: -2048 - 2047
    4 ms per 8 channels conversion speed
    removable barrier strip

  • A1S68DAI - 8 channel analog output, 4 - 20 mA
    (factory calibrated)
    resolution: 0 - 4095
    4 ms per 8 channels conversion speed
    removable barrier strip

  • A1S63ADA - 2 channel analog input, 1 channel analog output
    Combines 2 channels of A1S64DA with 1 channel of A1S62DA
    1 ms per channel digitizing / conversion speed

  • A1S62RD3 - 2 channel RTD input card, Three wire RTD
    0.025 degree C resolution
    -180 to +600 degree C range
    wire break detection
    40 ms per channel digitizing speed
    removable barrier strip

  • A1S62RD3 - 2 channel RTD input card, Four wire RTD
    0.025 degree C resolution
    -180 to +600 degree C range
    wire break detection
    40 ms per channel digitizing speed
    removable barrier strip

  • A1S68TD - 8 channel thermocouple input module
    channel to channel transformer isolation
    cold junction compensated with internal PT100 RTD
    thermocouple types K, E, J, T, B, R, S
    0.1 or 0.3 degree resolution depending on thermocouple type
    range depends on thermocouple (T = 0-350C, K=0-1200C, J=0-750C)
    400 ms per 8 channels digitizing speed
    removable barrier strip


All analog modules are opto-coupler isolated from the internal circuits.

Other special function modules:
  • A1SP60 - high speed pulse catch module, 16 channels NPN, 0.5 ms pulse trap

  • A1ST60 - analog timer module, 8 analog dials to manually set timing inputs

  • A1SI61 - interrupt module, 16 PLC program interrupt inputs, ON to OFF or OFF to ON

  • A1SD61 - high speed counter module
    single channel, 1 or 2 phase input
    5/12/24 volt input
    10 KHz or 50 KHz maximum speed (switch select)
    32 bit counter
    UP/DOWN preset, ring counter, cyclic counter, digital tachometer, limit switch output, counter hold function
    8 transistor outputs (open collector)

Several varieties of positioning module are available for servo or stepper motor applications - single, double and triple axis modules are available.

Remote I/O

Two different remote I/O systems are available - MINI-NET and I/O LINK.

MINI-NET is a high speed twisted pair data ring, 1.5 MBaud, which is capable of handling 512 I/O per data ring. Up to 8 master modules can be controlled by a single AnS PLC CPU. Remote I/O modules are available from 8 to 128 I/O in a single package - all types of input and output card have remote I/O counterparts. Analog input, analog output, RTD and Thermocouple input cards are available, as well. Maximum distance between stations is 100 meters for twisted pair connections, with much greater distances available using coaxial cable. Overall loop size is unlimited, and data repeaters are available for long distance connections.

I/O LINK is a smaller, less expensive remote I/O system. A single twisted pair data bus links remote I/O units at 38,400 Baud, with up to 128 I/O on a single twisted pair bus. Units may be connected electrically in any pattern, with a maximum distance from the base rack of 200 meters. No PLC program support is required, as remote I/O appears to the ladder program as if it were located on the PLC main rack. I/O LINK remote modules are available in 2, 4, and 8 input or output packages as well as 4 in/4 out packages. Inputs are 24 Volt DC, sink or source type, outputs are NPN transistor or relay. The I/O modules are very small - a 4 point input or output block is smaller than your fist (2 or 3 of them will fit in a 3 1/2" floppy disk box.)

Networking
PLC to PLC networking is available, using twisted pair or coaxial cable connections. 1 MBaud and 10 MBaud links are available, allowing data exchange among 64 PLC's on a single network, with up to 64 networks linked together into a factory-wide automation system. PLC data can be accessed over the network by communications modules, allowing operator interface terminals to display and control PLC's at remote locations.

Processors

CPUs

I/O Modules.

Communications Modules.

Remote I/O.